Язык документаанглийский

Figure 8. 3.3 Built-in Self-Test. Figure 9. 3.4 Reading out The Sensor Serial Number. Figure 10. 3.5 Sensor Start-up Behavior

Figure 8 3.3 Built-in Self-Test Figure 9 3.4 Reading out The Sensor Serial Number Figure 10 3.5 Sensor Start-up Behavior

32 предложений от 13 поставщиков
Биполярные транзисторы с изолированным затвором (IGBT) Dis High Perf IGBT
Триема
Россия
SGP40-D-R4 Датчик SSR
Sensirion
415 ₽
LIXINC Electronics
Весь мир
SGP40-D-R4
от 467 ₽
AliExpress
Весь мир
Модуль датчика газа GY-SGP30 SGP40 SGP41, TVOC eCO2 модуль для измерения диоксида углерода и формальдегида, инструменты
1 106 ₽
T-electron
Россия и страны СНГ
SGP40DR4
51 212 ₽
LED-драйверы MOSO для индустриальных приложений

Модельный ряд для этого даташита

Текстовая версия документа

link to page 10 link to page 10
Figure 8
Explanation of the VOC Index scale.
3.3 Built-in Self-Test
With the sgp40_execute_self_test command, users can perform an on-chip self-test for, e.g., in-line or end-of-line production testing. If this command is called when the sensor is in idle mode, the sensor returns to idle mode after the test (
Figure 9
). In case this command is called during VOC measurement mode (i.e., after calling the sgp40_measure_raw_signal command), the hotplate remains switched on thereafter. After 320 ms, the master can read a fixed data pattern (1 word + CRC byte) to check if the test was successful or not.
Figure 9
Possible ways of integrating the built-in self-test function.
3.4 Reading out The Sensor Serial Number
Every SGP40 sensor carries a unique serial number for identification purposes which is hard coded during sensor production. This number can be read out by using the sgp4x_get_serial_number command at any time in idle mode (
Figure 10
). After 1 ms, the chip responds with 3 words (each word followed by one CRC byte) which together constitute the serial number.
Figure 10
Process flow for reading out the serial number of the SGP40 sensor.
3.5 Sensor Start-up Behavior
The sensor starts powering-up after reaching the power-up threshold voltage of 1.7 V and enters idle mode after max. 0.6 ms. In this state, the sensor is ready to receive commands from the master. www.sensirion.com Version 1.1 – September 2021 10/19