Язык документаанглийский

Data Sheet. ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404. REGULATORY INFORMATION. Table 15. UL1. CSA (Pending). VDE

Data Sheet ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 REGULATORY INFORMATION Table 15 UL1 CSA (Pending) VDE

27 предложений от 13 поставщиков
Изоляторы Цифровые изоляторы
ЧипСити
Россия
ADUM6400ARIZ-RL
Analog Devices
875 ₽
AiPCBA
Весь мир
ADUM6400ARIZ-RL
Analog Devices
920 ₽
T-electron
Россия и страны СНГ
ADUM6400ARIZ
126 681 ₽
ADUM6400ARIZ-RL
Analog Devices
по запросу
Вебинар «Как выбрать идеальный силовой модуль: решения SUNCO для силовой электроники» (03.12.2024)

Модельный ряд для этого даташита

Текстовая версия документа

link to page 9 link to page 11 link to page 25 link to page 9 link to page 9 link to page 9
Data Sheet ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 REGULATORY INFORMATION
The ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 are approved by the organizations listed in Table 15. Refer to Table 20 and the Insulation Lifetime section for more information about the recommended maximum working voltages for specific cross-insulation waveforms and insulation levels.
Table 15. UL1 CSA (Pending) VDE
Recognized under UL 1577 component Approved under CSA Component Acceptance Notice #5A RW-16 package:2 recognition program Certified according to IEC 60747-5-2 (VDE 0884 Part 2):2003-01 (pending) Basic insulation, 846 V peak Single protection, 5000 V rms isolation Basic insulation per CSA 60950-1-07 and IEC 60950-1, RI-16-1 package:3 voltage 600 V rms (848 V peak) maximum working voltage Certified according to DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Reinforced insulation, 846 V peak RW-16 package: Reinforced insulation per CSA 60950-1-07 and IEC 60950-1, 380 V rms (537 V peak) maximum working voltage Reinforced insulation per IEC 60601-1, 125 V rms (176 V peak) maximum working voltage RI-16-1 package: Reinforced insulation per CSA 60950-1-07 and IEC 60950-1, 400 V rms (565 V peak) maximum working voltage Reinforced insulation per IEC 60601-1, 250 V rms (353 V peak) maximum working voltage File E214100 File 205078 File 2471900-4880-0001 1 In accordance with UL 1577, each ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 is proof-tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage detection limit = 20 μA). 2 In accordance with IEC 60747-5-2 (VDE 0884 Part 2):2003-01, each ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 in the RW-16 package is proof-tested by applying an insulation test voltage ≥ 1590 V peak for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884 Part 2):2003-01 approval. 3 In accordance with DIN V VDE V 0884-10 (VDE V 0884-10):2006-12, each ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 in the RI-16-1 package is proof-tested by applying an insulation test voltage ≥ 1590 V peak for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS Table 16. Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration Minimum External Air Gap (Clearance) L(I01) 8.0 mm Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L(I02) Measured from input terminals to output terminals, shortest distance path along body RW-16 Package 7.6 mm RI-16-1 Package 8.3 mm Minimum Internal Distance (Internal Clearance) 0.017 min mm Distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303, Part 1 Material Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Rev. A | Page 9 of 28 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAMS TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/5 V SECONDARY ISOLATED SUPPLY ELECTRICAL CHARACTERISTICS—3.3 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY PACKAGE CHARACTERISTICS REGULATORY INFORMATION INSULATION AND SAFETY-RELATED SPECIFICATIONS INSULATION CHARACTERISTICS IEC 60747-5-2 (VDE 0884 Part 2):2003-01 and DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Thermal Derating Curve RECOMMENDED OPERATING CONDITIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS TRUTH TABLE TYPICAL PERFORMANCE CHARACTERISTICS TERMINOLOGY APPLICATIONS INFORMATION PCB LAYOUT START-UP BEHAVIOR EMI CONSIDERATIONS PROPAGATION DELAY PARAMETERS DC CORRECTNESS AND MAGNETIC FIELD IMMUNITY POWER CONSUMPTION CURRENT LIMIT AND THERMAL OVERLOAD PROTECTION POWER CONSIDERATIONS THERMAL ANALYSIS INSULATION LIFETIME OUTLINE DIMENSIONS ORDERING GUIDE